Vue de la page 12
2042EDA Instruction Manual 7
Power Up
A red FAULT LED indicates an error situation and, when noted with
the other indicator LEDs, can indicate a specific problem area. Table 1
describes signal output and LED indications for the various input/ref-
erence combinations.
Table 2 provides the possible input and output conditions that result
from different input signals and conditions.
Table 1. Indicator LEDs and Conditions Indicated
LED Indication Condition
Off Normal operation
FAULT (red)
On continuously Module has detected internal fault
Long flash No input signal on input 1 or input 2
COMM (yellow)
Off No activity on frame communication bus
Long flash Location Command received by the module from a remote control system
Short flash Activity present on the frame communication bus
CONF (yellow)
Off Module is in normal operating mode
On continuously Module is initializing, changing operating modes or updating firmware
PWR (green)
Off No power to module or module’s DC/DC converter failed
On continuously Normal operation, module is powered
SIG 1 PRES
(green)
Off Indicates input 1 signal carrier missing or over EQ range
On Indicates input 1 signal carrier present
SIG 2 PRES
(green)
Off Indicates input 2 signal carrier missing or over EQ range
On Indicates input 2 signal carrier present
SIG (rear view)
(green)
Off Indicates both input 1 and 2 signal carriers missing
On continuously Indicates both input 1 and 2 signal carriers present
Long Flash Indicates input 1 missing, input 2 present
Short Flash Indicates input 1 present, input 2 missing
Table 2. Input and Output Conditions
Input Condition Output Condition
Serial Digital Component (SDI) Serial Digital Component (SDI)
HD Digital Component (SDI) HD Digital Component (SDI)
Other carrier (SMPTE 310M, DVB-ASI) Other carrier (SMPTE 310M, DVB-ASI)
No input signal Muted
Cable exceeding 200 – 300 meters Muted