7600 SD/HD/MHD-REF — Instruction Manual 73
Using a TFTP Server
Updating 7600 Software
When new software code for the 7600REF is available it can come in three
forms:
•Firmware
Changes to test patterns
Changes to menu structure
This code may be installed using the TFTP server method (see Preparing a
TFTP Server on page 71) with a series of programming files which are avail-
able from Technical Support.
Note It is not necessary to generate the log file as described earlier in the option
upgrading explanation.
Preparing to Update
Refer to the following sections to set up your 7600 for TFTP server function-
ality:
Download and install TFTP Server (see Using a TFTP Server on page 70)
Local Area Network considerations (see Local Area Networks on page 70)
Preparing a TFTP Server (see Preparing a TFTP Server on page 71)
Preparing the 7600REF
1. Power up the 7600REF and wait for initialization to complete.
2. Navigate the 7600 to Setup>>More>>Upgrades>>Server Address.
3. Enter the IP address of the TFTP server as previously noted and press
the
OK button.
Completing the Process
1. Navigate the 7600REF to Setup>>More>>Upgrades and choose the
appropriate option for the component being upgraded.
2. The message, upgrade successful, appears on the 7600REF LCD screen
once the upgrade process is complete.
3. The unit is now ready for use with the new code installed.